HEATERS: For Emergency in Case Power Fails

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago Hy-Lo Salamander burns either kerosene or range-oil; it is an ethylene risk; use kerosene; arrange a temporary vent to the outside; burn as bright a flame as possible. A74-114 Read More

HEATERS: Gas or Propane

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago A gas heater if exclusively methane can be used without venting; propane has up to 0.6% ethylene and needs proper venting A81-1093 Read More

HEATERS: Gas Space Units

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago A small unit providing 22-to-50,000 BTU in which the pilot light activates a small electrical pile which in turn activates a thermostat called Self Generating, or Capillary Tube, is described, to t... Read More

HEATERS: Infra-red New Types

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago They are efficient systems that use either natural gas or propane/butane mix to fire burners and a special pipe emits infrared waves which heat the plant benches, the floor, etc,x and not the air; ... Read More

HEATERS: Kerosene New Types

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago A 9000-BTU-per-hour heater can produce sulfur dioxide levels during overnight use, a principal air pollutant which is "controlled" by the U.S. Environment Protection Agency to prevent injury; venti... Read More

HEATERS: Quartz Electric Type

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago It is satisfactory for greenhouse use but perhaps is not adequate because it affects plants only in its pathway and costs more. A81-1093 Read More

HEATERS: Unvented

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago A heater using natural gas, no shortage of air and a clean burner is satisfactory. A81-266The flame consumes the oxygen in a tight greenhouse and the flame then does not burn properly and fumes beg... Read More

HEATERS: Wood-burning Furnaces

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago In Maine with a possible wind-chill factor of minus 80 dF, a furnace of 125,000 BTU, with hot air, taking a 30inch stick of wood, vented to the outside is described; specifications, names of suppli... Read More

HEATERS: Wood-burning Stove

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago It is apt to emit too much ethylene if it is not properly vented; burning wood is one of the worst sources of ethylene; it is now a crime to burn wood for heating purposes in London. A81-1436 Read More

ACID OR ALKALINE: Changing the Values

Author is Robert M. [Bert] Hamilton (Compiler), posted almost 8 years ago Various means can be used: tufa, a limestone form, can be added to paphiopedilums from limestone cliffs; bark composts acidify with age; peatmoss, pine needles, oak leaves in the mix produce acidit... Read More

Ailments

(931 articles)

Angraecoids

(41 articles)

Announcements

(4 articles)

Beginners

(21 articles)

Book Review

(4 articles)

Bulbophyllums

(2 articles)

Cattleya Alliance

(95 articles)

Conservation

(16 articles)

Culture

(1363 articles)

Curiosity

(49 articles)

Cymbidiums

(163 articles)

Dendrobiums

(29 articles)

General Discussion

(3 articles)

Oncidium Alliance

(64 articles)

Orchid Doctor

(3579 articles)

OrchidWiz

(27 articles)

Other Genera

(12 articles)

Paph Alliance

(78 articles)

Phalaenopsis

(83 articles)

Pleurothallids

(1 articles)

Propagation

(184 articles)

Scientific

(4 articles)

Site Navigation

(2 articles)

Species

(62 articles)

Travelogue

(2 articles)

Vandaceous

(26 articles)